135Appendix C Logicmaster 90–70, Rel. 3: Series 90–70 PLC Configuration for Remote Drops
With the Bus Controller selected in the rack display, zoom into the Bus Controller to
display the bus configuration screen.
In this example, the bus configuration screen shows the bus controller being
configured at its default location––bus address 31. To select a bus address for the
Remote I/O Scanner, move the cursor to the desired number and press F8 (Remote).
Note
If a Remote I/O Scanner has a bus address conflict on an operating bus,
it will not scan the modules in the remote drop until the fault is
cleared.
Press the Enter key to accept the Remote I/O Scanner (IC697BEM733).